Mechanical data
Measuring lengths (ML), mm | 70; 120; 170; 220; 270; 320; 370; 420; 470; 520; 620; 720; 820; 920; 1020; 1140; 1240; 1340; 1440; 1540; 1640; 1740; 1840; 1940; 2040 (mounting spar optional up to ML 1240, mandatory from ML 1340 to 2040) |
Accuracy grades to any meter within the ML (at 20°C) | ±5 μm |
Max. acceleration | 30 m/s |
Max. traversing speed | 2 m/s2 |
Required moving force | < 5 N |
Protection (EN 60529) | without compressed air: IP54 with compressed air: IP64 |
Weight | 0.4 kg + 0.8 kg/m |
Operating temperature | 0…+50°C |
Storage temperature | -20…+70°C |
Permissible humidity (non condensed) | 20…80% |
Permissible vibration (55 to 2000 Hz) | ≤ 100 m/s² |
Permissible shock (11 ms) | ≤ 150 m/s² |